Sentricon AlwaysActive Termite Baiting System

Sentricon AlwaysActive is an in-ground termite baiting system that is active from the moment it is installed. Sentricon IG (In-Ground) Termiticide Rods sit inside Sentricon Stations around the perimeter of a structure, so termites that forage into a station encounter a palatable termiticide bait immediately rather than a plain monitoring cartridge. The aim is colony elimination, and it can be achieved before termites have even been detected in the building.

What is Sentricon AlwaysActive?

Traditional termite management in Australia has relied on either a liquid chemical barrier (trenching and treating soil around the building) or a bait-and-monitor system where stations hold untreated timber until termites are found and then bait is added. Sentricon AlwaysActive combines the strengths of both approaches. Every station contains a high-density Sentricon IG Termiticide Rod from day one, so there is no waiting for a “hit” before termites start consuming active ingredient.

Because the system is baited, there is no mixing of termiticide, no trenching and no liquid applied to the soil around the home. Protection is continuous, all day, every day, for as long as the stations are maintained.

Sentricon AlwaysActive web banner showing in-ground termite stations around a home
Sentricon Stations are installed around the perimeter of the structure.

Key features and benefits

  • Active from installation. A termiticide rod is in every station from day one, providing continuous protection around the structure.
  • Colony elimination, not just a barrier. The active ingredient is carried back and shared throughout the colony, so the goal is to eliminate the colony rather than simply deflect foragers.
  • Highly palatable bait. Sentricon IG Termiticide Rods have been demonstrated to be highly palatable to termites, especially once they have aged and weathered in the ground.
  • Long-lasting in Australian conditions. The rods have been shown to remain effective for up to five years in Australian conditions.
  • No mixing, no trenches, no liquid termiticide. Installation avoids the disruption of trenching and drilling associated with chemical soil barriers.
  • Fast installation and monitoring. Stations are quick to install and check, giving technicians more time on the tools and more capacity to grow the business.
  • An effective, safe and affordable option for homeowners facing one of the most common risks to Australian houses.

How the active ingredient works

The active ingredient in Sentricon IG Termiticide Rods is hexaflumuron, a chitin synthesis inhibitor. Chitin is a major component of the termite exoskeleton, and every termite must produce new chitin each time it moults. Hexaflumuron interferes with chitin production, so affected termites cannot complete the moult and die.

Three characteristics make this mode of action well suited to baiting:

  1. Delayed effect. No matter how much bait a termite eats, toxicity is not evident until it tries to moult. Termites keep feeding, keep recruiting nest mates to the station and keep carrying bait home.
  2. Efficient transfer. Termites share food throughout the colony by trophallaxis (mouth-to-mouth feeding). Hexaflumuron moves through the colony the same way, reaching individuals that never visit a station.
  3. Non-repellent. Termites do not die in or near the rod, so death is never associated with the station. Unaffected termites are not repelled and continue feeding until the colony collapses.
Sentricon AlwaysActive banner featuring Sentricon IG Termiticide Rods and stations
Sentricon IG Termiticide Rods contain hexaflumuron in a high-density bait matrix.

Where it fits in Australian termite management

Subterranean termites, including Coptotermes species, are responsible for most structural termite damage in Australia, and many homes sit within foraging range of a colony. Sentricon AlwaysActive suits situations where a full chemical soil barrier is impractical or undesirable, for example:

  • Homes on concrete slabs or with paving, decks and landscaping that would need to be drilled or lifted for a liquid treatment.
  • Sites where the homeowner prefers a non-liquid approach or where soil treatment is constrained by drainage, water courses or access.
  • Properties where the customer wants an ongoing, monitored management program rather than a one-off treatment.
  • Situations where colony elimination, rather than a barrier alone, is the objective.

As part of an integrated termite management program, the system should be paired with a thorough timber pest inspection to AS 3660 and AS 4349.3, correction of conducive conditions (moisture, timber-to-ground contact, stored timber against walls) and a scheduled station-inspection program. The Sentricon technical documents below cover site assessment, station placement, construction considerations and maintenance schedules.

Safety and compliance

  • Sentricon IG Termiticide Rods are a registered termiticide and must only be used by licensed pest management technicians in accordance with the APVMA-approved label and the state or territory licensing requirements that apply where the work is done.
  • The active ingredient sits inside a sealed station in the ground, so there is no liquid termiticide mixing or spraying on site, and exposure to occupants and the technician is minimal.
  • Follow the label and the Sentricon Tech Manual for PPE, handling, storage and disposal of used rods.
  • Provide the homeowner with the relevant documentation, including the inspection and maintenance schedule, in line with AS 3660 requirements for termite management systems.

Downloads

Technical resources for professional pest managers:

Resources to share with homeowners:

Frequently asked questions

How is Sentricon AlwaysActive different from a monitor-and-bait system?

In a conventional bait-and-monitor system the stations hold untreated timber and bait is only added once termites are found. With Sentricon AlwaysActive, every station holds a hexaflumuron termiticide rod from the day it is installed, so termites begin feeding on active bait at first contact.

Why don’t the termites avoid the bait?

Hexaflumuron only acts when a termite moults, so termites do not die at the station and nothing links the bait with death. The bait is non-repellent and highly palatable, which keeps termites feeding and recruiting until the colony is eliminated.

How long do the rods last?

Sentricon IG Termiticide Rods have been shown to be effective for up to five years in Australian conditions. Stations still need to be inspected on the schedule set out in the Sentricon Maintenance guide and the product label.

Can any pest controller install Sentricon AlwaysActive?

Installation must be carried out by a licensed pest management technician working to the label and the Sentricon Tech Manual. Contact your Garrards branch about supply and any accreditation requirements.

Available from Garrards

Garrards supplies Sentricon AlwaysActive stations and Sentricon IG Termiticide Rods to professional pest managers across Australia, along with the technical support to help you put the system to work in your termite management business.

Contact your local Garrards branch

Frequently asked questions

How is Sentricon AlwaysActive different from a monitor-and-bait system?

In a conventional bait-and-monitor system the stations hold untreated timber and bait is only added once termites are found. With Sentricon AlwaysActive, every station holds a hexaflumuron termiticide rod from the day it is installed, so termites begin feeding on active bait at first contact.

Why don't the termites avoid the bait?

Hexaflumuron only acts when a termite moults, so termites do not die at the station and nothing links the bait with death. The bait is non-repellent and highly palatable, which keeps termites feeding and recruiting until the colony is eliminated.

How long do the rods last?

Sentricon IG Termiticide Rods have been shown to be effective for up to five years in Australian conditions. Stations still need to be inspected on the schedule set out in the Sentricon Maintenance guide and the product label.

Can any pest controller install Sentricon AlwaysActive?

Installation must be carried out by a licensed pest management technician working to the label and the Sentricon Tech Manual. Contact your Garrards branch about supply and any accreditation requirements.