Termidor High Pressure Device (HPD) by rega for Termidor HE

The Termidor High Pressure Device (HPD) by rega is a purpose-built injection rig for applying Termidor HE. Developed by rega in conjunction with BASF, it delivers Termidor HE at a minimum pressure of 800 psi, which allows hole spacings of up to 600 mm through concrete and paving. Fewer holes means less drilling, less patching and a faster job, with the same coverage under the slab.

Termidor High Pressure Device (HPD) by rega injection unit
The Termidor High Pressure Device (HPD) by rega.

What the HPD by rega does

Conventional termiticide injection through drilled holes relies on relatively low pump pressure, so holes must be drilled close together to achieve a continuous treated zone. Termidor HE uses BASF’s patented and exclusive Advanced Polymer Technology, which is designed to help the termiticide spread further through the soil profile. Combined with the high, preset operating pressure of the rega HPD, this is what allows Termidor HE to be applied at 600 mm hole spacings.

Termidor HE and rega High Pressure Device promotional banner showing wider hole spacings
Termidor HE plus the rega HPD: wider hole spacings, same coverage.

Key benefits for termite treatments

  • Enhanced performance. The wider spacings, combined with the high-pressure delivery, distribute Termidor HE further from each injection point for a continuous treated zone.
  • Better for the homeowner. Fewer drill holes means less damage to slabs, paving, tiles and paths, and a tidier finished job, which translates into higher customer satisfaction.
  • Speed and efficiency. Wider spacings let you cover larger areas more effectively, significantly reducing the time and labour needed for each application.
  • Lower labour costs. Less drilling reduces wear and tear on drills and bits and cuts operating costs. rega advises that new or pre-drilled treatments can see a 50 to 75 per cent labour saving, even where existing hole spacings are 200 to 300 mm apart.

Works with your existing vehicle setup

The HPD by rega is designed as a cost-effective addition to a vehicle you already have on the road. There is no need to rebuild your rig: connect your current spray unit to the rega high pressure device using a 2S socket and you are ready to inject at high pressure.

Termidor HPD by rega specifications

Component Detail
Pump Preset high-pressure pump
Power Honda motor
Operating pressure with Termidor HE Minimum 800 psi
Injector tips included 5 mm x 150 mm; 6.5 mm x 200 mm; 8 mm x 200 mm; 9.5 mm x 200 mm
Hose 15 m high-pressure hose to connect to a J-foot injector with high-pressure gun
Connection to existing spray unit 2S socket

Where it fits in Australian termite management

Chemical soil treatments to existing buildings remain one of the core tools for managing subterranean termites in Australia, and drilling and injecting through slabs, paths and paving is one of the most labour-intensive parts of that work. The HPD by rega is aimed squarely at that task: perimeter and internal slab injection on established homes, treatments to pre-drilled structures where the original spacings were 200 to 300 mm, and larger commercial slabs where hole count drives the quote.

Good practice does not change with the equipment. Inspect thoroughly first, confirm the construction type and slab edge details, identify service penetrations and moisture sources, and record the treatment on the required durable notice and in your treatment report. The wider spacing is a label-based application rate for Termidor HE with this device, not a licence to skip parts of the perimeter.

Safety and compliance

  • Termidor HE must be used only as directed on the APVMA-approved label, including the specified hole spacings, application rates and the equipment conditions for the 600 mm spacing. Download the updated label below and read it before the first job.
  • Termite treatments must be carried out by a licensed pest management technician under the relevant state or territory legislation.
  • High-pressure injection equipment can cause injection injuries. Wear the PPE specified on the label, keep hands and feet clear of the injector tip, never point the gun at a person, and ensure hoses and fittings are rated for the operating pressure and inspected regularly.
  • Petrol-engine equipment must be operated in a well-ventilated area, never inside an enclosed subfloor or garage.

Frequently asked questions

Do I need a new vehicle setup to run the HPD?

No. The rega HPD is designed to be added to an existing rig. Your current spray unit connects to the HPD via a 2S socket.

Can I use the 600 mm spacing with any termiticide?

The 600 mm spacing is specific to Termidor HE applied with the high pressure device. Always follow the label for whichever product you are applying.

What injector tips are supplied?

Four tips are included: 5 mm x 150 mm, 6.5 mm x 200 mm, 8 mm x 200 mm and 9.5 mm x 200 mm, covering a range of drill sizes and slab thicknesses.

Downloads

Available from Garrards

The Termidor High Pressure Device by rega and Termidor HE are available through Garrards branches across Australia. Talk to your branch about setting the HPD up on your vehicle and about training on the updated Termidor HE label.

Contact your local Garrards branch

Frequently asked questions

Do I need a new vehicle setup to run the HPD?

No. The rega HPD is designed to be added to an existing rig. Your current spray unit connects to the HPD via a 2S socket.

Can I use the 600 mm spacing with any termiticide?

The 600 mm spacing is specific to Termidor HE applied with the high pressure device. Always follow the label for whichever product you are applying.

What injector tips are supplied?

Four tips are included: 5 mm x 150 mm, 6.5 mm x 200 mm, 8 mm x 200 mm and 9.5 mm x 200 mm, covering a range of drill sizes and slab thicknesses.