Formulation
- Formulation type: suspension concentrate (SC)
- Insecticide mode of action group: Group 2B (phenylpyrazole)
- Poisons schedule: Schedule 5 (CAUTION)
Overview
Termidor HE Residual Termiticide is a 96 g/L fipronil soil termiticide for Pest Management Professionals. It protects new and existing domestic and commercial structures from subterranean termites. It is registered by the APVMA (Approval No. 80820/146381) and must be used by licensed pest control operators only.
It creates a continuous chemical soil treated zone, horizontal and vertical or as an external perimeter, under and around a structure in line with AS 3660.1 (pre-construction) and AS 3660.2 (post-construction). The same product is also registered for reticulation systems, poles and fence posts, termite nests, and active termite workings in cavities and timber.
The 'HE' stands for High Efficiency. BASF's Advanced Polymer Technology (APT) helps the fipronil move further through the soil. In practice, this means shallower trenches and, with the Termidor High Pressure Device, wider drill-hole spacing through concrete. The result is less digging, less drilling and less disruption on site, while still building a treated zone that meets AS 3660.
Product Highlights
- Shallower trenches: because the product spreads further through soil, the bottom 150 mm of a vertical treated zone can stay unexcavated. For example, a 300 mm depth to the top of the footing needs only a 200 mm deep trench. That means less excavation, less soil handling and faster perimeter jobs.
- Fewer holes through concrete: with the Termidor High Pressure Device, holes for under-slab and under-path rodding can be spaced up to 600 mm apart (500 mm in clay soils). Conventional rodding allows up to 450 mm (350 mm in clay). Fewer holes means less labour, fewer plugs and less visible damage to the client's slabs and paths.
- Minimum eight-year protection from one product: when applied as a soil treatment according to the label, it is effective against subterranean termites for at least eight years. It is also registered for pre-construction, post-construction, reticulation, pole, nest and active-workings treatments.
Target pests
- Subterranean termites, including but not limited to:
- Coptotermes acinaciformis
- Mastotermes darwiniensis
- Schedorhinotermes spp.
Where to use
All states. It is for use around domestic and commercial structures, as set out in the label's Directions for Use.
- Pre-construction: chemical soil treated zones under and around new buildings and structures (AS 3660.1)
- Post-construction: chemical soil treated zones under and around existing buildings and structures, including beneath concrete slabs and paths (AS 3660.2)
- High-pressure soil treatments, pre- and post-construction, using the Termidor High Pressure Device
- Approved reticulation systems installed to the manufacturer's specifications and the AS 3660 series
- Poles and fence posts in contact with soil, both existing and newly installed
- Termite nests in trees, stumps, posts, power or utility poles and mounds
- Cavity, nest and active termite treatments, e.g. active workings in in-service timber, infested wall cavities and voids under concrete
- Not for internal surfaces
Application
Mix and apply exactly as the label directs. Rates, volumes and mix concentrations are on the label.
- Mixing: half fill the spray tank with water, add Termidor HE, stir, then top up to volume. Equipment must be leak-free and clean of other chemical residues.
- Spray equipment: calibrate to deliver a low-pressure, high-volume coarse spray.
- Vertical treated zones: trenching, treating the trench and treating the backfill is the preferred method. Use soil rodding only where trenching is not possible or practical.
- Under slabs and paths: drill and inject with a slab injector or soil rod fitted with a 3- or 4-way multi-directional tip. Rotate the rod during application and plug the holes afterwards.
- Termidor High Pressure Device: allows high-pressure soil injection and injection through concrete. The device must generate at least 800–1200 psi when applying through concrete.
- Reticulation: pump through an approved system. Delivery pipes must be placed so the horizontal and vertical treated zones are continuous and complete.
- Foam: foam-generating equipment can supplement liquid treatment where a continuous zone is hard to achieve, such as soil subsidence under slabs, large cavities or nests.
- Difficult soils: scarify heavy clay. Very heavy soils can be replaced with treated sandy loam. Pre-moisten dry, sandy or porous soils. Non-ionic wetting agents may help in difficult-to-wet soils.
- Slopes: form a furrow along the contour to prevent run-off.
- Active termite treatments: apply only where live termites are present. Follow immediately with a continuous AS 3660.2 soil treatment once activity has been eliminated.
Safety
CAUTION – Schedule 5 poison. Keep out of reach of children. Read the safety directions before opening or using. For licensed pest control operators only.
- Personal protective equipment (PPE) when opening the container, preparing spray and using the prepared spray: chemical-resistant clothing buttoned to the neck and wrist, a washable hat, a half-facepiece respirator with combined dust and gas cartridge, and elbow-length PVC or nitrile gloves.
- Hazards: will irritate eyes and skin, and repeated exposure may cause allergic disorders. Harmful if swallowed or inhaled. May cause damage to the central nervous system through prolonged or repeated exposure.
- Do not re-enter treated areas until the spray has dried. Keep residents and pets out of rooms being treated.
- Remove pets and animals, and cover or remove food, water containers, fish ponds and aquariums before spraying.
- Before treating, identify ducts, vents, plumbing, sewer, drainage and electrical lines, and do not puncture or contaminate them. Avoid application around edible plants.
- Do not apply if heavy rain or storms likely to cause run-off are forecast within 48 hours.
- Highly toxic to aquatic life and bees. Prevent rinse water and run-off from entering drains or waterways.
- After each day's use, wash gloves, contaminated clothing and respirator.
- First aid: Poisons Information Centre 13 11 26. BASF specialist emergency advice: 1800 803 440 (toll free, all hours).
FAQ
- Can I tank mix Termidor HE with other products? No tank mixing with other insecticides is recommended, because it may affect how the product behaves and performs. Non-ionic wetting agents and foaming agents may be used where the label allows, such as in difficult-to-wet soils, under-slab voids and cavities. Garrards notes that Termidor HE can be used alongside Trelona ATBS as part of a broader termite management program.
- Do I need the Termidor High Pressure Device to use it? No. You can apply Termidor HE with conventional spraying and trenching, standard rodding equipment, foam equipment or approved reticulation systems. The High Pressure Device is what unlocks the wider drill spacing through concrete (up to 600 mm) and the label's additional high-pressure mix option.
- Will a single treatment fix an active infestation, and what are its limits? Active termite treatments are not designed as stand-alone treatments. A continuous AS 3660.2 soil treatment should follow once activity has been eliminated. Termites may stay active for several weeks after crossing the treated zone, due to delayed mortality. Disturbed zones must be re-treated, and inspections are recommended at least annually because treated zones can be bridged or breached. Other limitations: no internal surface application, possible staining behind plasterboard, and uneven distribution when rodding in heavy clay, where trenching is preferred. Real-world protection periods also depend on termite pressure, climate, soil and later soil disturbance.
Pack Size
Termidor HE Residual Termiticide: 2.34 L bottle (listed for sale as 2L).
- How to order: Garrards product code TERMIDOR/HE2